Regulator Impletionis Solaris MPPT MC Series W
SPECIFICATIO
| Modellum (MPPT MC-W-) | 20A | 30A | 40A | 50A | 60A | |
| Categoria producti | Proprietates Moderatoris | MPPT (punctum maximae potentiae observationis) | ||||
| Efficacia MPPT | ≥99.5% | |||||
| Potentia subsidiaria | 0.5W ~ 1.2W | |||||
| Proprietates Inputorum | Maxima tensio ingressus PV (VOC) | DC180V | ||||
| Punctum tensionis oneris incipe | Tensio pilae + 3V | |||||
| Punctum tutelae tensionis inputatae humilis | Tensio pilae + 2V | |||||
| Punctum tutelae supertensionis | DC200V | |||||
| Punctum recuperationis tensionis excessivae | DC145V | |||||
| Characteres Oneris | Genera Accumulatorum Selectibilia | Plumbum acidum obsignatum, accumulator gelatinosus, inundatus | ||||
| (Pila Gelata Praedefinita) | (Alia genera pilarum etiam definiri possunt) | |||||
| Currens oneris aestimatus | 20A | 30A | 40A | 50A | 60A | |
| Compensatio Temperaturae | -3mV/℃/2V (praedefinitum) | |||||
| Ostende et | Modus ostentationis | Ostentus retroilluminationis codicis segmenti LCD altae definitionis | ||||
| Communicatio | Modus communicationis | Porta RJ45 octo-clavorum/RS485/monitorationem programmatum computatralium sustinet/ | ||||
| Alii Parametri | Functio protegendi | Protectio tensionis input-output supra / sub | ||||
| Praeventio praesidii contra inversionem nexus, praesidii contra defectum pilae, etc. | ||||||
| Temperatura Operationis | -20℃~+50℃ | |||||
| Temperatura Reponendi | -40℃~+75℃ | |||||
| IP (Praesidium Ingressus) | IP21 | |||||
| Strepitus | ≤40dB | |||||
| Altitudo | 0~3000m | |||||
| Maxima magnitudo nexus | XX mm2 | Triginta millimetra2 | ||||
| Pondus Nettum (kg) | 2.3 | 2.6 | ||||
| Pondus Grossum (kg) | 3 | 3.5 | ||||
| Magnitudo Producti (mm) | 240*168*66 | 270*180*85 | ||||
| Magnitudo sarcinae (mm) | 289*204*101 | 324*223*135 | ||||
SPECIFICATIO
| Modelum MLW-S | Decem kW | 15KW | 20 kW | 30 kW | 40 kW | 50 kW |
| Tensio Systematis | 96VDC | 192VDC | 384VDC | |||
| CARICATOR SOLARIS | ||||||
| Maximus Inputus PV | 10KWP | 15KWP | 20KWP | 30KWP | 40KWP | 50KWP |
| Currens Aestimatus (A) | 100A | 100A | 100A | 100A | 120A | 140A |
| Introitus AC | ||||||
| Tensio Ingressa AC (Vac) | 3/N/PE, 220/240/380/400/415V Triphasis | |||||
| Frequentia Ingressus AC (Hz) | 50/60±1% | |||||
| Exitus | ||||||
| Potentia Aestimata (kW) | Decem kW | 15KW | 20 kW | 30 kW | 40 kW | 50 kW |
| Tensio (V) | 3/N/PE, 220/240/380/400/415V Triphasis | |||||
| Frequentia (Hz) | 50/60±1% | |||||
| Distortio Harmonica Totalis Tensionis | THDU <3% (Plenum onus, onus lineare) | |||||
| THDU <5% (Plenum onus, onus non lineare) | ||||||
| Regulatio Tensionis Exitus | <5% (Onus 0~100%) | |||||
| Factor Potentiae | 0.8 | |||||
| Capacitas Oneris Superflui | 105~110%, 101 minuta; 110~125%, 1 minutum; 150%, 10 secunda. | |||||
| Factor cristae | 3 | |||||
| Data Generalia | ||||||
| Efficacia Maxima | >95.0% | |||||
| Temperatura Operandi (°C) | –20~50 (deminutio potentiae >50°C) | |||||
| Humiditas Relativa | 0~95% (non condensans) | |||||
| Protectio Ingressus | IP20 | |||||
| Altitudo Operativa Maxima (m) | 6000 (deminutio potentiae >3000m) | |||||
| Ostendere | LCD+LED | |||||
| Methodus refrigerationis | Refrigeratio aeris coacti callida | |||||
| Protectio | Tensio AC et DC supra/sub, tensio AC supra posita, circuitus brevis AC, temperatura supra posita, etc. | |||||
| EMC | EN 61000-4, EN55022 (Classis B), | |||||
| Salus | IEC60950 | |||||
| Dimensiones (P*L*A mm) | 350*700*950 | 555*750*1200 | ||||
| Pondus (kg) | 75 | 82 | 103 | CLXXXI | 205 | 230 |
PROPRIETATES
MPPT Altae Efficaciae: Indagatores Punctorum Potentiae Plurium (MPPT) efficiunt ut potentia emissa ex ordine tabularum solarium conversionem energiae 20% ~ 30% augeat.
Alta fides: Microprocessore provecto uti potes ut "MPPT + SOC" duplicem moderationem oneris intelligentem et optimizatam consequaris, quo productum stabile et fidum sit.
Intelligenter administratio oneris: Modum oneris coniungens currentem constantem et tensionem constantem adopta ut efficax oneratio et vita batteriae curentur.
Alta efficacia: MOSFET et PWM mollis commutatoris necnon technologiae rectificatoris synchroni cum consumptione energiae humilis adoptantur, efficaciam operationis systematis efficaciter augentes.
Intelligenter: Initium automaticum per recognitionem illuminationis (facultativum) – systema configurare potest initium automaticum oneris si solis insufficientis sit, ut nebula, pluvia, nocte etc.
Protectiones: Supercharge / overdischarge, circuitus brevis, overload, nexus inversus, protectio fulminis TVS etc.
Fortis adaptabilitas ad ambitum.